Lightweight board lamination
Bonding MgO and Lightweight Board Panels
Magnesium-oxide, gypsum and calcium-silicate boards vary in porosity, moisture and surface dust. Validate the exact board and facing rather than relying on a generic bond-strength claim.
Controlled starting point: MPU-20
| Item | Published value |
|---|---|
| System | 1K · no mixing |
| Viscosity | 8000–9000 mPa·s |
| Coating guide | 120–160 g/m² |
| Cure guide | 4–8 hours |
These values come from the MPU-20 gypsum/lightweight-board TDS. They do not establish a universal bond strength or guarantee every MgO formulation.
Trial checklist
- Record board supplier, density, moisture and surface condition.
- Confirm facing material and any coating or oil.
- Trial coating weight and pressure without board damage.
- Inspect failure mode after cure and required ageing.